small_tab1_Serie MFPCR

Conforme à VDI 6022

small_tab1_Serie MFPCR

MFPCR

POUR LES EXIGENCES LES PLUS CRITIQUES CONCERNANT LA PURETÉ DE L'AIR INTÉRIEUR, LES ZONES BLANCHES ET LES APPAREILS

 

HEPA and ULPA filters as high-efficiency particulate filters for the separation of suspended particles in clean room systems. Used for industrial, research, medical, pharmaceutical, and nuclear engineering applications.

  • Filter classes H14, U15, U16
  • Performance data tested to EN 1822
  • Meets the hygiene requirements of VDI 6022
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Perfect adjustment to individual requirements due to variable pleat depths
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Automatic filter scan test
  • Fitting into filter fan units, clean room workbenches, or operating theatre ceilings

Application

Application

  • Mini Pleat filter panel type MFPCR for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply and extract air in clean room systems with controlled air cleanliness and airflow
  • Particulate filter: Final filter for the most critical requirements of air cleanliness and sterility in areas such as industry, research, medicine, pharmaceuticals, and nuclear engineering

Special characteristics

  • Ideal pleat geometry of the filter medium
  • Low initial differential pressure at high filtration performance
  • Low-turbulence airflow on the downstream side
  • Filter scan test ensures leak-free construction as well as compliance with the stated efficiency and differential pressure

Description

Filter classes

  • Particulate filters H14, U15, U16

Construction

  • ALB: Frame made of extruded aluminium sections (depth 69 mm)
  • ALC: Frame made of extruded aluminium sections (depth 78 mm)
  • ALG: Frame made of extruded aluminium sections (depth 90 mm)

Special construction:

  • Filter frame with knife edge profile
  • Filter frame with U-channel section, filled with a gel as fluid seal

Options

  • FT: Pleat depth
  • PU: Protection grid on the upstream side
  • PD: Protection grid on the downstream side
  • PB: Protection grid on both sides
  • CSU: Continuous seal on the upstream side
  • CSD: Continuous seal on the downstream side
  • CSB: Continuous seal on both sides
  • OT: Oil mist test (only for filter class H14)

Construction features

  • Perimeter continuous seal on the upstream side as standard
  • Some constructions with optional continuous seal on the downstream side or on both sides
  • Protection grid made of expanded metal, can be fitted on the downstream or upstream side or both sides as required

Materials and surfaces

  • Filter media made of high-quality, moisture-resistant glass fibre papers, pleated
  • Spacers made of thermoplastic hot-melt adhesive provide a uniform spacing of the pleats
  • Joint sealing compound made of permanently elastic two-component polyurethane adhesive
  • Frame made of extruded aluminium sections

Information technique

  • Technical data
  • Specification text
  • Order code
mfpcr

 

Mini Pleat filter panels MFPCR for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply and extract air in clean room systems with controlled air cleanliness and airflow.

Use as particulate filters, i.e. main or final filters, for the most critical requirements of air cleanliness and sterility in areas such as industry, research, medicine, pharmaceuticals, and nuclear engineering. The filter media are made of high-quality, moisture-resistant glass fibre papers, with spacers made of thermoplastic hot-melt adhesive.

Different pleat depths enable perfect adjustment to individual requirements.

Mini Pleat filter panels for clean room technology available in standard and special sizes, filter classes H14, U15, U16.

As standard, Mini Pleat filter panels for clean room technology are fitted with a perimeter continuous seal on the upstream side.

Some constructions are available with an optional seal on the downstream side or on both sides, or with a protection grid, fitting as required.

As standard, Mini Pleat filter panels for clean room technology are subjected to an automatic filter scan test.

Special characteristics

  • Ideal pleat geometry of the filter medium
  • Low initial differential pressure at high filtration performance
  • Low-turbulence airflow on the downstream side
  • Filter scan test ensures leak-free construction as well as compliance with the stated efficiency and differential pressure

Materials and surfaces

  • Filter media made of high-quality, moisture-resistant glass fibre papers, pleated
  • Spacers made of thermoplastic hot-melt adhesive provide a uniform spacing of the pleats
  • Joint sealing compound made of permanently elastic two-component polyurethane adhesive
  • Frame made of extruded aluminium sections

Construction

  • ALB: Frame made of extruded aluminium sections (depth 69 mm)
  • ALC: Frame made of extruded aluminium sections (depth 78 mm)
  • ALG: Frame made of extruded aluminium sections (depth 90 mm)

Special construction:

  • Filter frame with knife edge profile
  • Filter frame with U-channel section, filled with a gel as fluid seal

Sizing data

  • Filter class
  • Volume flow rate [m³/h]
  • Initial differential pressure [Pa]
  • Nominal size [mm]
mfpcr

Téléchargements

Information produit

Certificats

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Partager la page

Recommander cette page

Recommander cette page en envoyant un lien par mail.

Les champs marqués d'un (*) sont obligatoires.

Partager la page

Merci pour votre recommandation !

Votre recommandation a été envoyée et devrait arriver dans les plus brefs délais.

Contact

Nous sommes à votre disposition

Veuillez préciser votre message et le type de demande
Tel.: +32 (0) 2/522 07 80

Les champs marqués d'un (*) sont obligatoires.

Contact

Merci pour votre message !

Votre message a été envoyé et sera traité dans les plus brefs délais.
Notre département de traitement des demandes prendra contact avec vous dès que possible.
Pour les questions d'ordre général concernant les produits ou services, vous pouvez aussi nous appeler :
Tel.: +32 (0) 2/522 07 80

Contact

Nous sommes à votre disposition

Veuillez préciser votre message et le type de demande
Tel.: +32 (0) 2/522 07 80

Pièce jointe (max. 10MB)

Les champs marqués d'un (*) sont obligatoires.

Contact

Merci pour votre message !

Votre message a été envoyé et sera traité dans les plus brefs délais.
Notre département de traitement des demandes prendra contact avec vous dès que possible.
Pour les questions d'ordre général concernant les produits ou services, vous pouvez aussi nous appeler :
Tel.: +32 (0) 2/522 07 80