SIF_img_01psd.psd.link

SCF_img_19psd.psd.link

Cell frame with quick release fastener

SCF_img_21psd.psd.link

Standard cell frame with quick release fasteners, variant SCF-E-25

SCF_img_09psd.psd.link

Standard cell frame with spring clips, variant SCF-B-25

Tested to VDI 6022

SIF_img_01psd.psd.link
SCF_img_19psd.psd.link
SCF_img_21psd.psd.link
SCF_img_09psd.psd.link

SIF

Fitting of filter elements for the separation of coarse and fine dust


Standard cell frames for pocket filters, Mini Pleat filter inserts, activated carbon filter inserts, Mini Pleat filter panels with plastic frames. For installation into ventilation and air conditioning systems

  • Highly variable as parts of various dimensions can be combined

  • Robust construction

  • Total compensation of tolerances due to perimeter groove in standard cell frame

  • Cell frames with a groove provide various tensioning options depending on the filter frame depth

  • Easy handling and secure sealing due to 4 special clamping elements and a foamed, closed-cell, silicone-free continuous seal

  • Meets the hygiene requirements of VDI 6022

 

Optional equipment and accessories

  • Stainless steel construction

Updating order code
Save configuration
Calculate price
Updating technical data
  • Media
Specification text:
Updating specification text
Show complete text Hide complete text
Initialize order code

General information

Application

  • Filter wall for ventilation and air conditioning systems

  • Fitting of filter elements for the separation of coarse and fine dust

  • Fitting of filter elements for the adsorption of gaseous odorous substances and contaminants

  • Filter wall for pocket filters, Mini Pleat filter inserts, activated carbon filter inserts, Mini Pleat filter panels with plastic frames



Nominal sizes

  • Number of cell frames – horizontally

  • Number of cell frames – vertically



Variants

  • B: Standard cell frame with spring clips

  • E: Standard cell frame with quick release fasteners

  • Tensioning depth: 25 mm



Construction

  • GAL: Galvanised steel

  • STA: Stainless steel



Useful additions

  • Suitable filter elements to be ordered separately

  • Pocket filters made of non-woven chemical fibres (PFC)

  • Pocket filters made of non-woven synthetic fibres (PFS)

  • Pocket filters made of NanoWave® medium (PFN)

  • Pocket filters made of non-woven glass fibres (PFG)

  • Mini Pleat filter inserts (MFI)

  • Activated carbon filter inserts (ACFI)

  • Mini Pleat filter panels (MFP, construction PLA)



Construction features

  • 4 clamping elements for secure sealing between the cell frame and the filter elements

  • Cell frame with perimeter groove

  • Base elements in various sizes

  • Standard cell frames of the same size can be combined into a filter wall

  • Maximum height: up to 7.5 standard cell frames

  • Maximum width: up to 13 standard cell frames



Materials and surfaces

  • Standard cell frames, installation subframes, and flat steel stiffeners made of galvanised sheet steel or stainless steel



Commissioning

  • The filter wall consists of individual standard cell frames

  • The installation subframe is to be inserted into the groove of the cell frame and bolted into place at the corners

  • The flat steel stiffeners provide static stability

  • The installation frame is to be sealed to the structure



Standards and guidelines

  • Hygiene meets the requirements of VDI 6022, VDI 3803, DIN 1946 Part 4, ÖNORM H 6021 and ÖNORM H 6020, SWKI VA 104-01 and SWKI 99-3, and EN 16798



Maintenance

  • Maintenance-free as construction and materials are not subject to wear


Technical information

Function, Specification text, Order code

  • Function
  • SPECIFICATION TEXT
  • ORDER CODE

The filter wall consists of individual standard cell frames. The installation subframe is inserted into the groove of the cell frame and bolted into place at the corners. The flat steel stiffeners provide static stability.

 

 

 


Specification text

Filter wall type SIF for installation into ventilation and air conditioning systems. Fitting of filter elements for the separation of coarse dust and fine dust and for the adsorption of gaseous odorous substances and contaminants. Filter wall consisting of standard cell frames with perimeter groove as base element, installation subframes, and flat steel stiffeners. 4 clamping elements for secure sealing between the cell frame and the filter element. The installation subframe is inserted into the groove of the cell frame and bolted into place at the corners. The flat steel stiffeners provide static stability. The filter wall meets the hygiene requirements of VDI 6022.




Materials and surfaces

  • Standard cell frames, installation subframes, and flat steel stiffeners made of galvanised sheet steel or stainless steel



Construction

  • GAL: Galvanised steel

  • STA: Stainless steel


SIFB25GAL / 2,5×2
||||||
123456

1 Type
SIF Filter wall 

2 Variant

B
 Standard cell frame with spring clips
E Standard cell frame with quick release fasteners 

3 Tensioning depth [mm]
25 

4 Material
GAL Galvanised steel
STA Stainless steel 

5 Number of cell frames – horizontally
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6

6 Number of cell frames – vertically
1
1.5
2
2.5
3
3.5
4
4.5
5

   

Dimensions, Product details

  • DIMENSIONS
  • PRODUCT DETAILS
(1)(2)(3)(4)
BHhorizontalvertical592 × 592287 × 592592 × 287kg
6106101115
61091511.5118
610122012210
610152512.52111
610183013313
610213513.53116
610244014417
9196101.51118
91912201.522215
91918301.533323
91924401.544429
122561021210
122591521.52215
1225122022418
1225152522.54222
1225183023625
1225213523.56229
1225244024833
1225274524.58240
12253050251043
15356102.512111
153512202.524224
153518302.536334
153524402.548444
153530502.5510561
184061031313
184091531.53323
1840122032626
1840152532.56333
1840183033937
1840213533.59344
184024403412
48
1840274534.512360
18403050351564
21456103.513116
214512203.526232
214518303.539346
214524403.5412460
214530503.5515583
245061041417
245091541.54430
2450122042835
2450152542.58444
24501830431249
2450213543.512458
24502440441663
2450274544.516481
24503050452087
27636104.514119
276312204.528240
276318304.5312358
276324404.5416475
276330504.55205104
306861051521
306891551.55537
30681220521043
3068152552.510555
30681830531560
3068213553.515573
30682440542079
3068274554.5205101
306830505525108
337712205.5210249
337718305.5315370
337724405.5420490
337730505.55255126
36831220621251
3683152562.512666
36831830631873
3683213563.518687
36832440642494
3683274564.5246121
368330506530130

  • The filter wall consists of individual standard cell frames

  • The installation subframe is to be inserted into the groove of the cell frame and bolted into place at the corners

  • The flat steel stiffeners provide static stability

  • The installation frame is to be sealed to the structure

Downloads

product information

certificates

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request.
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Contact

We are here for you

Please specify your message and type of request.
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +32(0)2 522 07 80 | E-mail: info@trox.be